Installation Type Ducted
Communication Feature Yes
Communication Feature Type ComfortBridge Technology compatible
DOE Regional Compliance North;Southeast;Southwest
Serialized Flag Yes
Item Stocking Unit of Measure (UOM) EA
Pallet Qty 2
Country of Origin USA
US HTS Code 8415.90.8065
Product Description – (PIM)
16 SEER, Air Conditioner, 2 Ton, Two Stage
AHRI Reference Number 201511904
Cooling Capacity – (Nominal) 23400 Btu/H
EER (HSVTC) 12.2
ENERGY STAR® Certified Yes
SEER (HSVTC) 14
Cooling Operation Range – (Std. Max) 125 °F
Cooling Operation Range – (Std. Min) 55 °F
Rated Cooling Condition – (Ambient DB) 95 °F
Rated Cooling Condition – (Ambient WB) 75 °F
Rated Cooling Condition – (Room DB) 80 °F
Rated Cooling Condition – (Room WB) 67 °F
Subcooling Temp at Service Valve 6 °F
Superheat Temp at Service Valve 8 °F
Compressor LRA 62.9 A
Compressor RLA 10.0 A
Control Voltage Conduit Size 1/2 in;3/4 in
Current Type AC
Max Overcurrent Protection 20 A
Max Voltage 253 V
Min. Circuit Amps 13.6 A
Min. Voltage 197 V
Outdoor Fan FLA 1.1 A
Power Frequency 60 Hz
Power Phase 1 Ph
Power Supply Conduit Size 1/2 in;3/4 in
Power Voltage 208/230 V
Air Flow Rate (High) – Cooling 800 ft³/min
Air Flow Rate (Low) – Cooling 600 ft³/min
Compressor Sound Blanket Yes
Compressor Stages Two Stage
Compressor Type Scroll
Condenser Fan Blade Count 3
Condenser Fan Diameter 26 in
Condenser Fan RPM 845 r/min
Dimensions – (Unit Depth) 29-1/4 in
Dimensions – (Unit Height) 32-1/2 in
Dimensions – (Unit Width) 29-1/4 in
Energy Source Electric
ETL Listed Yes
Expansion Device TXV
Indoor Orifice Size N/A in
Motor Speed Type Two-Speed PSC
Sound Pressure (High) – Cooling 71 dBA
Sound Pressure (Low) – Cooling 68 dBA
Weight – (Unit) 197 lb
Condenser Fan Horsepower 1/6 metric hp
Cooling Capacity – (Rated) 23400 Btu/H
Cooling Capacity – (Sensible) 18200 Btu/H
Cooling Input Power 1.92 kW
Sensible Heat Ratio – (S/T) 0.732
Tonnage 2
Additional Refrigerant Charge – (oz/ft) 0.6
Factory Std. Refrigerant Charge 92 oz
Indoor TXV Kit TX2N4A
Long Line Set Length – (Equivalent) 150 ft
Pipe Size Gas 3/4 in
Pipe Size Liquid 3/8 in
Refrigerant Pre-Charged Line Length 15 ft
Refrigerant Type R-410A
Standard Line Set Length – (Max) 80 ft
Standard Line Set Length – (Vertical) 25 ft
Valve Connection Type Sweat
Valve Size Liquid (O.D.) 3/8 in
Valve Size Suction (O.D.) 3/4 in
Vertical Length – (OD Above ID) 25 ft
Vertical Length – (OD Below ID) 80 ft
Proposition 65 Label Yes
Dimensions – (Case Depth) 30.50 in
Dimensions – (Case Height) 34.50 in
Dimensions – (Case Width) 30.00 in
Weight – (Case) 168.000 lb